{"id":4476,"date":"2025-07-17T21:56:03","date_gmt":"2025-07-17T18:26:03","guid":{"rendered":"https:\/\/www.vazeshtp.com\/axial-flow-fans-novax-acp-acg\/"},"modified":"2025-07-17T21:56:03","modified_gmt":"2025-07-17T18:26:03","slug":"axial-flow-fans-novax-acp-acg","status":"publish","type":"post","link":"https:\/\/www.vazeshtp.com\/en\/axial-flow-fans-novax-acp-acg\/","title":{"rendered":"Axial Flow Fans NovAx ACP-ACG"},"content":{"rendered":"<p style=\"text-align: left;\">The NovAx ACP and ACG are unidirectional axial flow fans for conventional, industrial and marine use.<\/p>\n<p style=\"text-align: left;\">Optionally the NovAx ACP and ACG fans are available as smoke fans . The NovAx ACP and ACG smoke exhaust fans are for conventional, industrial and marine environments and suitable for operation during fires in carparks , commercial and industrial buildings, tunnels and more. The design is tested and approved to meet requirements for smoke exhaust.  <\/p>\n<p style=\"text-align: left;\">The ACG smoke fans are fitted with an additional guide vane arrangement to increase fan efficiency.<\/p>\n<p style=\"text-align: left;\"><strong>Product facts<\/strong><\/p>\n<ul>\n<li dir=\"ltr\" style=\"text-align: left;\">Mounting<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">ACP: For wall or bulkhead <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">ACG: For duct connection <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Fan sizes<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">ACP and ACG fans: 14 sizes from \u00d8250 to \u00d81600 mm <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">ACP and ACG smoke fans: 12 sizes from \u00d8400 to \u00d81600 mm <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Seven hub sizes from \u00d8160 to \u00d8578 mm<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Fan casing thicknesses of 2.5, 3 or 4 mm depending on size<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Airflow rates<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">0.1 to 65 m3\/s<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">350 to 235.000 m\u00b3\/h<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Pressures up to 2000 Pa<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Efficiencies up to 83%<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">F200, F300 and F400 approved for smoke extract<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Adjustable blade angles<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Integrated inlet cone<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">ACG: Additional guide vane arrangement <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Corrosion categories according EN-ISO 12944-2:2017<\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Standard: C3 <\/li>\n<li dir=\"ltr\" style=\"text-align: left;\">Optional: C4 or C5 <\/li>\n<\/ul>\n<p style=\"text-align: left;\">Accessories for mounting, connection, sound attenuation, safety and regulation<\/p>\n<p style=\"text-align: left;\">Also available as type NovAx ACN for duct installation or the 100% reversible NovAx ARN<\/p>\n<p style=\"text-align: left;\">Product configuration with AirBox<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The NovAx ACP and ACG are unidirectional axial flow fans for conventional, industrial and marine use. Optionally the NovAx ACP and ACG fans are available as smoke fans . The NovAx ACP and ACG smoke exhaust fans are for conventional, industrial and marine environments and suitable for operation during fires in carparks , commercial and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4270,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[],"class_list":["post-4476","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products-en"],"_links":{"self":[{"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/posts\/4476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/comments?post=4476"}],"version-history":[{"count":0,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/posts\/4476\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/media\/4270"}],"wp:attachment":[{"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/media?parent=4476"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/categories?post=4476"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.vazeshtp.com\/en\/wp-json\/wp\/v2\/tags?post=4476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}